thiagoralves
We’re getting ready to move from OpenPLC Editor 4.0.6-beta to 4.1.0, and this one is huge. We’re officially dropping the “beta”, and for good reason. OpenPLC Editor 4.1.0 brings a ton of new features that make it our most capable release yet. In fact, OpenPLC is doing things that even commercial PLC IDEs haven’t achieved yet. And we’re doing it completely open source and free for everyone!
 
Here's what's coming:
 
Python Function Blocks
Yes, Python! For the first time in a PLC IDE, you can write Function Blocks in Python alongside your IEC code. We’ve also built a full smart autocomplete and static analysis (powered by Pyright) right into the editor. Python blocks run asynchronously, so your PLC core keeps its real-time performance while you benefit from the power of Python for data, analytics, APIs, and more.
 
C/C++ Function Blocks with Arduino API support
Write your Function Blocks in C or C++ and, if you’re targeting Arduino, you can use the entire Arduino API (Serial.print(), digital I/O, everything). These blocks run natively inside the runtime core, with full real-time performance.
 
Built-in REST API integration
The OpenPLC Runtime v3 was upgraded and received a backport of the OpenPLC Runtime v4 REST API (the v4 runtime is not available to the public yet). This means you can now upload programs, start/stop the PLC, and view runtime logs directly from the editor. No need to export .st files or login on the browser anymore to make changes to your programs.
 
Real-Time Debugger
Visualize your PLC logic live with animated rungs, real-time variable watch, and live plotting of signal values. Works across all targets, from microcontrollers to Linux and Windows runtimes.
 
We’re incredibly proud of how far the OpenPLC ecosystem has come. This release takes it to another level, with a platform that rivals (and in some areas surpasses) commercial PLC systems. And it's all open. All free. Stay tuned!
 
Screenshot 2025-10-23 at 12.23.04 PM.png
 
Screenshot 2025-10-23 at 12.24.54 PM.png
 
Screenshot 2025-10-23 at 12.33.45 PM.png
 
Screenshot 2025-10-23 at 12.38.30 PM.png
 
Screenshot 2025-10-23 at 12.47.54 PM.png
Reply 14 0
thiagoralves
While the runtime is connected, you need to click on the Serial Port combo box and pick one of the options from the list. COM ports on the runtime have unix-based names instead of windows-based names. Most likely "COM10" is not on the list, therefore the runtime cannot use it. Look for something like /dev/ttyS9 (for COM10). We will work on an update that translates unix-based names to windows-based names for the runtime running on Windows. This will make the process more straightforward for Windows users.
Reply 0 0
r1s8k
That's beautiful.
 
I think the run time app is for the online control, if I'm right. I hope you to intergrate its software in the main openplc app. It'll be a massive programming ide with integrated funtionalities; like, serial communication, online communication, on-app simulation .. etc.
Reply 0 0
Li.kg
When I was using version 4.1.2, I found that the SFC language option was unavailable. Is this feature still under development?
Reply 0 0
thiagoralves
When I was using version 4.1.2, I found that the SFC language option was unavailable. Is this feature still under development?
Yes
Reply 0 0
arumade1990
I apologize for being a bit dense, but is this now the official version to use? I started doing some heavy work with OpenPLC again for a project and was having some odd problems on the Arduino extension side of things with it recognizing a library I was trying to test with it. I'm still have the v3.xx editor. Should I go ahead an update to the new editor? I was originally holding off until the build was released as a stable official release.
Reply 0 0
thiagoralves
Yes, v4 is the official version and the recommended one for future projects. The v3 editor is not maintained anymore and won’t get any bug fixes or improvements
Reply 1 0
arumade1990
Yes, v4 is the official version and the recommended one for future projects. The v3 editor is not maintained anymore and won’t get any bug fixes or improvements
Awesome! While I'm excited to get into the new editor, I do wish I would've paid more attention of it's release before writing a bunch of logic in the old editor. I'm assuming that its not backwards compatible since theres so much new stuff. Regardless, I'm looking forward to dive into it!
Reply 0 0
Li.kg
Thiago Alves, hello! I saw on openplc-editor-4.1.3 that the hardware for the Arduino platform is already supported. This is an excellent support. Also, an attempt was made to build the Arduino development board project. During the compilation process, it was noticed that arduino-cli and xpack-arm-none-eabi-gcc were used. I would like to know if there are any relevant documentation regarding the compilation process for the Arduino platform?
Reply 0 0
thiagoralves
There isn’t any documentation about it, but the source code is pretty straightforward. Compilation is achieved through arduino-cli. OpenPLC generates the C source files from the PLC project, sends that to arduino-cli and then arduino-cli does the rest.
Reply 0 0
FutureHorizon
Hi Thiago,
I just upgraded to 4.1.4 and updated the runtime and I just noticed that debugging now has live values at the variable!
 
BRAVO !!! 👍👍👍👍👌👌👌👌🙏🙏🙏🙌🙌
 
Amazing!
Reply 0 0
thiagoralves
Thanks! Live values for Structured Text and Instruction List are already on the development branch and should come soon to v4.1.5
Reply 0 0
FutureHorizon
A very useful feature would be in the configuration pane to be able to see the runtime version running and if an update would be in order to use all features of the editor, or if it is required for use of the current editor version.
Do editor and runtime go together in terms of version compatibility? I would expect so. Than a compatibility status indicator to show if they are compatible.
I'm currently experimenting with an offline runtime running on an automation system that does not have direct access to the internet, so it's not super easy to just update the runtime every time I update the editor. The Appimage is more easily transferable, where the runtime requires internet access.
Reply 0 0
FutureHorizon
And looking very much forward to structured text live values! Instruction list I don't really use, personally 🙂 Wasn't that canned in the latest IEC-61131-3 ?
Reply 0 0
fg71
I believe the Instruction List was removed from 4th edition of IEC-61131-3 released 2025.
Reply 0 0
thiagoralves
Yes, IL is not on the standard anymore, but since we already support it, I don't see any reason to remove it for now.
Reply 0 0
Reply